Гарантия на печатную плату ABB SDCS-PIN-48-SD один год
Предмет номер.:
SDCS-PIN-48-SDОплата:
T/TПорт доставки:
Xiamen ChinaВремя выполнения:
IN STOCKЗаказ (минимальный заказ):
1our website : https://www.kerienplc.com/
Kerien Automation Co., Ltd. is located in the beautiful coastal city-Xiamen, Fujian, China. It is one of the beautiful coastal tourist cities in Southeast China.
We are a supplier of industrial automation parts. We focus on PLC modules and DCS cards, and undertake PLC control cabinets and inverter control cabinets. The brands are as follows:
Invensys Foxboro,Invensys Triconex,Rockwell Allen-Bradley Relianc,Schneider Modicon,ABB,Siemens,GE FANUC,Yaskawa,Bosch Rexroth,Westinghouse,Woodward,Ovatin...etc.
The grounding screw is insulated due to the rubber between the cabinet body and the base, and the shielding busbar is insulated from the base. The field control station shall be grounded according to the regulations. That is, they are respectively connected to the grounding busbar of the field control station. The power ground of I/O cabinet and UPS are connected to the same ground to ensure equipotential. 2. Each hardware equipment operator station, engineer station, network switch, server host, system display, etc. shall be grounded by shell or directly connected to the electrical grounding grid. 3. The 40 terminal of the analog module of the I/O module, namely the negative terminal of DC 24V, is connected to the logic grounding bus, the logic grounding bus is connected to the shielding ground, and then connected to the general grounding bus. 4. Shielding ground The protective ground of the field control station shall be connected from the grounding screw under the cabinet to the grounding branch line, and the shielding ground of the field control station shall be connected from the grounding bus bar to the public connection board. 5. Grounding resistance test The resistance of the grounding system shall be tested to ensure that the grounding can meet the requirements of the control system manufacturer. 1 The shell, instrument panel, cabinet, box, box, cable trough, protective tube, support, base and other normal and uncharged metal parts of the electrical instrument that may have dangerous voltage due to insulation damage shall be grounded for protection. For local instruments and switches with power supply voltage not higher than 36V, protective grounding is not required when there are no special requirements in the design documents.
AO820 3BSE008546R1
AO845A 3BSE045584R1
AO890 3BSC690072R1
AO895 3BSC690087R1
DI810 3BSE008508R1
DI811 3BSE008552R1
DI814 3BUR001R54R1 2SE 1454R1 3518 3520 35 БСЭ008550Р2 ДИ825 3БСЭ036373Р1
ДИ830 3БСЭ013210Р1
Предыдущий:
Модуль памяти АВВ 07KR51Следующий:
Встроенный предохранитель ABB REM620Если у вас есть вопросы или предложения, пожалуйста, оставьте нам сообщение, мы ответим вам, как только сможем!
Категории
новые продукты
AB 1768-PA3 входной источник питания ПЛК промышленного управления Читать далее
2094-BC07-M05-M 2094-BC07-M05-S Сервопривод American AB Kinetix6200 2094BC07M05S 2094BC07M05S Читать далее
MFC075BOM2 MFC075B0T1 MFC075BOM16 Инверторная плата Emerson Читать далее
SPMA1422 Модуль преобразователя привода серии Unidrive SPM Читать далее
Технические параметры преобразователя частоты EMERSON EV1000-4T0037G Читать далее
© Авторские права: 2025 Kerien Automation Co., Ltd. Все права защищены.
Поддерживается сеть IPv6